EAT-CH200V GenInterlock Cutler Hammer Generator Interlock Kit Vertical Throw Main 150 or 200 amp Panel Generator Interlock Kit

Free shipping on orders over $29.99

$69.95

$ 27 .99 $27.99

In Stock

About this item

  • Fits Cutler Hammer Vertical throw main 150 or 200 amp
  • 2 1/4 inch spacing between main and branch breaker
  • Met lab listed E113887
  • Kit includes, Interlock, drill bit, labeling and retaining strap for generator breaker
  • PLEASE Verify panel type by checking second picture


Generator Interlock kit for Cutler Hammer Vertical Throw main 150 or 200 amp panel with 2 1/4 spacing from main to branch breaker. CH series panels. Met lab listed E113887 Panel and breakers not included


Shelly Laughlin
Reviewed in the United States on December 31, 2021
Trick to install is to mark where to drill holes with front panel on, then after drilling the first hole, put a screw in temporarily so the second hole will line up, then repeat for third hole.
Zachary Garretson
Reviewed in the United States on September 19, 2020
This is a good quality interlock kit, but way too expensive for what it is. I could see $35.00, but $73.00 is a bit steep for what it is. Also, it is not designed quite right. I installed it by the book, but when the main breaker was locked out in the off position, it still would not allow the generator breaker to turn on. I had to cut 3/16" off the left side of the bottom tab with an angle grinder to give enough clearance for the 2 pole 30A generator breaker to be turned on. After I made that alteration, it works perfectly. I see this is a common issue. The depth of the top slot for the main breaker is 1/2". The width of the tab that blocks the generator breaker should also be 1/2". They should be the same. Eaton needs to change this design flaw.
KP
Reviewed in the United States on February 13, 2020
Can't install level due to cutouts on interlock. Must be installed so bottom angles toward center of panel in orderto clear generator breaker. Apparently other consumers had same problem. Believe Mfg. needs to make generatorbreaker cutout 1/4" deeper which would correct the problem.
HonestReviews86
Reviewed in the United States on February 18, 2019
I was looking at model that cost twice as much from a different maker and was tempted to make my own at that price, but when I saw this one that accomplishes the same goal for half the price, I went with it. It first my old cutler-hammer vertical switch box perfectly. I lost one of the screw nuts and emailed them about it and they shipped me a new set for free within a week. Great customer service!
Phatfill
Reviewed in the United States on December 25, 2018
Make certain that you follow the instructions for drilling as there's little leeway for errors. With that said, it works great and is a great alternative to a transfer switch.
Patrick P.
Reviewed in the United States on December 5, 2017
Interlock kit worked perfectly to keep my generator bypass system operating safely! Good instructions and easy to operate.
Rebecca
Reviewed in the United States on November 7, 2017
Easy to install, easy directions. Took about 20 minutes as long as you have home electrical knowledge. I like that it is safe and comes with all items to meet NEC code. I was surprised on how tight fitting the interlock is, great job on the tolerances for breaker cutouts, make safety fool proof.
Diverreb
Reviewed in the United States on April 2, 2016
Easy to install and works as advertised. Prevents the Generator Breaker from being turned on while the Main Breaker is also on. Makes it impossible to feed Generator Power back and out to the main line. It is a fairly inexpensive solution for the lock out and allows use of your entire breaker box circuits.