Your cart is empty.
Your cart is empty. Progesterone precautions and information reference:
1. Draw blood, at least 1 ml of venous blood. Too little may result in poor serum centrifugation. Centrifuge, 4000 RPM for 15 minutes.
2. Serum pipette must be quantified to 80ul. This quantity must be accurate to 80ul, otherwise it will affect the testing effect.
3. When extracting serum with a pipette, take the serum according to the first gear. Release the serum by pressing to the end. Make sure it's a one-time drain, release 80 micro-liters of serum, otherwise it will affect the data.
4. Drop the serum into the reagent card of the round hole. When the serum flows into the test strip, insert the round hole into the slot of the instrument card, and click the standard button on the machine to enter the test mode. 15 minutes to produce results, the best breeding data is between 15-25 (If you do not understand the data, please contact us promptly via Amazon email.).
5. It should be noted that the operating environment and the temperature of the test paper storage are about 20-30℃. Do not heat the machine locally.
6. Please do not compare the test results of this machine with the local veterinary test values, as the system of the testing machine is different. Follow the operation process we prompted, and the test value is between 15 and 25, which is the optimal breeding period.