Taidacent Din Rail Type RS485 Modbus RTU PLC Control 0-20mA 4-20mA Signal Generator Current Signal Generator DC24V Adjustable Valve Analog Current Simulator with Display (RS485 4-20mA Output)

Free shipping on orders over $29.99

$34.58

$ 15 .99 $15.99

In Stock

1.:Only 0-20ma Output


  • Model Number 4 to 20ma signal generator Power supply DC 15V to 28V Power consumption Less 2W
  • Output current range 0mA to 22mA adjust (default 0-20/4-20mA) Output adjustment accuracy 0.1mA, error <0.05mA
  • Load sampling resistance <500 ohm Working Temperature 0-40C,RH<80%
  • Press and hold the knob for 2 seconds to enter the parameter setting, the parameter number "FO1" is displayed, when the parameter number is displayed, rotate the knob "+" and "-" to modify the parameter number, then press the knob to modify the parameter value, and press the knob again to save and exit ;
  • Adopt standard MODBUS-RTU message format, slave mode address 1-127 (factory setting 1), baud rate 2400-57600 (factory setting 9600), no parity; There is no 1209 terminal resistance inside. When the bus speed is far away and there are many devices, the user needs to connect the terminal resistance to make the transmission more stable; the use of high-quality shielded twisted pair can increase the anti-interference ability of communication; MODBUS-RTU message format , commands and examples:



Product Description

1.1 DC24V supply voltage range: DC15V---DC28V

1.2 AC AC220V (optional) power supply range: AC85-264V or DC110-370V

1.3 Power consumption <2w

1.4 Output current range: 0 to 22mA (it can be set, default setting 0-20/4-20mA); Output voltage range:0 to 10V (it can be set, default setting 0-5V/0-10V)

1.5 Output adjustment accuracy 0.1mA, error <0.05mA, load sampling resistance <500 ohm. Output regulation accuracy 0.1V, error <0.05V, output maximum load current <20mA

1.6 Working environment: 0-40℃, relative humidity <80%

Size

voltage current signal generator

Connecting

Voltage Current signal current Connecting

System operation (turn clockwise for "+" and turn counterclockwise for "-", press the knob for "OK")

Press and hold the knob for ⒉ seconds to enter the parameter setting, the parameter number "F01" is displayed, when the parameter number is displayed, rotate the knob "+" and "-" to modify the parameter number, then press the knob to modify the parameter value, and press the knob again to save and exit ;

Parameter description table

Parameter for voltage current signal generator

RS485 communication

RS485 slave address 1 byte
Function code 1byte 03 or 06 command
Data N byte
CRC check 2byte stanrdard crc16 start value 0xFFFF
03 multiple registers command for example: query 20 registers starting from address 0, return 40 bytes of data
Send 01 03 00 00 00 14 45 C5
Return 01 03 28 00 00 04 BO 04 BO 04 BO 00 01 00 00 00 01 00 01 00 02 00 0000 00 00 01 03 20 00 0A 00 00 00 00 00 00 00 00 00 00 00 00 98 EE
06 Set single register command for example: set the value of register 3 to 2000, return the command directly