Shopping Cart

Your cart is empty.

Your cart is empty.

High Voltage Differential Probe DP Series oscilloscopes Probe 100Mhz/150Mhz/200Mhz oscilloscopes Probe DP1500/DP700/DP3000/DP7000/DP701/DP1501/DP3001/DP702/DP1502/DP3002(DP700 100Mhz)

Free shipping on orders over $29.99

$299.00

$ 99 .00 $99.00

In Stock

1.Size:Dp700 100mhz


  • ◆Micsig High Voltage Differential Probe DP/DP Originated from cutting-edge SigOFIT technology
  • ◆The Micsig DP DP series HV differential probe has very low noise floor
  • ◆The oscilloscopes Probe with excellent high-voltage amplitude-frequency characteristics
  • ◆Micsig DP DP High Voltage Differential Probe with industry-leading common mode rejection capability
  • ◆Excellent Bandwidth Flatness;High Accuracy, High CMRR;Low Noise;Quick Zero;BNC Interface;Type C



Product Description

Miscig MDP/DP Series High Voltage Differential Probe

1

Miscig DP/MDP Series High Voltage Differential Probe

Except for the model name, all other parameters and appearance of the DP series are exactly the same as the MDP series.

Micsig high-voltage differential probe -- DP series covering bandwidth from 100MHz to 500MHz, differential voltage up to 7000Vpk. Based on the leading optical isolation probe technology, the DP series has very low noise, excellent amplitude-frequency characteristics and high CMRR.

With standard BNC interface, the DP series can work with any oscilloscope; probe body is only 2CM thick, protected by metal housing, achieves strong anti-interference ability. One-press auto Zero, dual-range and overload alarm design. High impedance designed, the single-ended impedance of the input end to the signal output BNC interface > 8MΩ, single-ended capacitance < 8pF, meets various safety test requirements. 5MHz bandwidth limit function can effectively filter out high-frequency noise and interference, ideal for switching power supplies, various high-frequency and high-voltage floating or isolated signal tests.

The previous model DP10007 has been upgraded to DP700. *The previous model DP10013 has been upgraded to DP1500. *The previous model DP20003 has been upgraded to DP3000.

Note: These models have not only been upgraded in performance (see parameter table), but also in appearance, which has been newly designed and made more compact and exquisite. When placing orders, please handle them according to the new model numbers.


1
Wide Applications

● Floating measurements

● High voltage isolation measurements

● Switching power supply design

● Power converter design

● Inverter, UPS power supply

● Motor drive design

  • ● Electronic power and electric drive experiments
  • ● Low-voltage electrical appliances
  • ● Welding, electroplating power supply ● Electronic ballast design
  • ● Induction heating, induction cooker ● CRT display design

Except for the model name, all other parameters and appearance of the DP series are exactly the same as the MDP series.

Key Features

DP series has high input impedance and low input capacitance, minimized load effect, greatly improved the accuracy of the differential signal. High common mode rejection capability, able to meet floating measurements of high common mode voltage at high frequencies.

  • Standard BNC interface, work with any oscilloscope.
  • Improves signal-to-noise ratio, meet more test requirements. BNC Interface
  • Dual Range Selection
  • Short-circuit the test leads, press Zero button, the probe can be zeroed very fast.
  • series high-voltage differential probe has very low noise floor, excellent
  • High Voltage Differential Probe DP Series Originated from Micsig's cutting-edge SigOFITTM technology
  • The DP series probe has excellent bandwidth flatness, amplitude fluctuation less than 0.5dB within its half bandwidth range, even in high frequency bands can also maintain high accuracy.

2

USB Power Supply

Powered directly by oscilloscope's USB port via type-C cable.

Overvoltage Alarm

LED flashes, buzzer "beeps" rapidly, indicating an over-range alert.

Compact & Exquisite

Much smaller than traditional differential probes.

1

Low Noise

Short circuit the input ends, connect to CH1. Set both attenuation ratio at 50X, vertical scale at 250mV/div, time base at 1ms, input impedance is 1MΩ, observe the noise floor:

* Noise: 40.62mV (RMS) at full bandwidth

1

High Accuracy, High CMRR

High input impedance and low input capacitance, minimized load effect, greatly improved the accuracy of the differential signal. High common mode rejection capability, able to meet floating measurements of large common mode voltage at high frequencies.

CH1: @ 100KHz, 207.7V, output common mode signal amplitude 94.62mV, CMRR > -60dB

1

Excellent Bandwidth Flatness

The DP series probe has excellent bandwidth flatness, amplitude fluctuation less than 0.5dB within its half bandwidth range, even in high frequency bands can also maintain high accuracy.

1

Except for the model name, all other parameters and appearance of the DP series are exactly the same as the MDP series. :Applications

 Floating measurements  High voltage isolation measurements  Switching power supply design  Power converter design  Inverter, UPS power supply  Welding, electroplating power supply Electronic ballast design  Motor drive design Induction heating, induction cooker CRT display design Low-voltage electrical appliances  Electronic power and electric drive experiments


JHoney
Reviewed in the United States on March 2, 2025
I like having this probe as a high impedance measuring device.The HV end box has a plastic body with matte black coating. The scope end is a metal box covered in stickers. The cable between the modules is about 150cm (59 in) long. Both feel very sturdy.The high voltage banana leads are all silicone insulation. The permanently attached leads are about 17cm (7 in) long. Included tips are more suited for larger devices like power equipment.The buttons on the scope end have a tactile click, but don't always activate with the click, requiring more pressure.On over-voltage the scope end will beep and flash an LED.Operation is similar to a regular probe, but you have to zero the device before use by shorting the leads and pressing a button.The 5 MHz bandwidth limit lets you filter out higher frequency noise. It's just a push button toggle with LED indicator.These have unusual range multipliers that older/cheaper hardware might not support.
Ana
Reviewed in the United States on December 18, 2024
Great product, reliable, very good communication and good price
Recommended Products

$569.00

$ 99 .00 $99.00

5.0
Select Option