Your cart is empty.
Your cart is empty. For Refrigerators Models & Serial Number:
NDR 1062 serial # 921146080 - 921146087
NDR 1292 # 921148101 - 921148110
RM 2354 # 921145025 - 921145031
RM 2451 # 921140112 - 9211401126
RM 2454 # 921140114 - 921140119
RM 2551 # 921142101 - 921142110
RM 2554 # 921142107 - 921142108
RM 2620 # 921575002 - 921575013
RM 2652 # 921144101 - 921144140
RM 2662 # 921144103 - 921144110
RM 2663 # 921144105 - 921144106
RM 2820 # 921596009 - 921596011
RM 2852 # 921146101 - 921146154
RM 2862 # 921146103 - 921146108
RM 3862 # 921146109 - 921146160
RM 2351
For Dometic Black Box Part:
The 3850415.01 is designed to replace part number 3850415-xxx. Do not attempt to replace any other Black Box Board part number with this board.
NOTE: Use as a REPLACEMENT for PREVIOUSLY PROPERLY INSTALLED 3850415.01 circuit board with their 2 way & 3 way kits.
1.In GAS mode with NO FLAME SENSE, the timing is as follows:
A. 1st "45" sec ignition try - turn ON check light.
B. "2" min wait - turn OFF check light.
C. 2nd "45" sec ignition try - turn ON check light.
D. "2" min wait - turn OFF check light.
E. 3rd "45" sec ignition try - turn ON check light.
F. "30" min wait with the check light ON.
G. Turn check light OFF and repeat steps "A-E".
The check light will be reset if:
a. Refrigerator is turned OFF and back ON.
b. A different mode is tried and returned to GAS mode.
2.In GAS mode: when a flame is sensed on any try, entire "3 try" sequence of "A - H" will be reset.
3.In "DC" mode with AES or AMES eyebrows, DC mode will be functional for 12V DC+. If DC voltage falls below 11.0V for 10 sec+, either while cooling or not; DC mode light will begin to FLASH, DC element will be disconnected or inhibited from operating. Refrigerator is undisturbed, DC operation cannot be reestablished until DC voltage rises above 13.2V for 10 sec+.