Shopping Cart

Your cart is empty.

Your cart is empty.

MCAMPAS Furnace Pilot Burner Ignitor Igniter Replacement for Honeywell Q3451B1103 Q3451B1178 Q3451B1186, Compatible with Raypak 002003F Pool & Spa Heaters Pilot Kit

Free shipping on orders over $29.99

$31.90

$ 13 .99 $13.99

In Stock
  • Compatibility: This pilot assembly is compatible with Raypak IID pool heaters and fits both natural gas and propane models
  • Easy Installation: Straightforward replacement of the pilot light assembly for seamless repairs or maintenance
  • Replacement Part: Same for Genuine OEM component designed to ensure proper fit and functionality. comes with a smaller orifice nozzle is the propane orifice, pilot natural Or propane can be converted by changing the orifice
  • Reliable Operation: Helps maintain efficient and consistent performance of your pool or spa heater
  • Long-Lasting Quality: Constructed with durable materials to provide extended service life
  • Replacement for Manufacturer Parts: Raypak 053A,053B,055A,055B,105A,105B,105B,106A,151,153,155A,155B/C,156A,181,183,183A,185B/C,206A,261,263,263A,265B/C,266A,331,333.333A,335A,335B/C,336A,401,403,403A,405A,405B,405B/C,406A,268,408,R185,R185A,R185B,R265,R265A,R265B,R335,R335A,R335B,R405.R405A,R405B,RP2100
  • Widely used:Used On Raypak Electronic Natural & Propane Gas Models -Fit for 3E366, 3E367, 3E368, 3E406, 3E4404, 3E468, 4E454, 4E455, 4E456, 9E796, S8600F, S8600H, S8600M, S8610F, S8610H, S8610M, S8610U, S8660D, 8660E, S8670D, S8670E, QVEF030, QVEF045, QVEF060, QVEF075, QVF030, QVF045, QVF060, QVF075
  • Replace Number:002003F Pilot Natural/Propane Lid Burner ignitors for natural gas furnace replace J38R04578-001, J38R04578-001RC, 4365864A, Q3451U1000, 1011483, etc
  • Universal for Honeywell replacement furnace Ignitor Igniter Q3451B1103



Product Description

Are Pool Heat Pumps

Install the correct orifice and compression Fitting

  • Orifice: Natural gas orifice nozzle & LPG Propane orifice nozzle -Provided for you to use interchangeably
  • Compression fitting 1/4 in OD pipe tubing
asd

Connect the Ignition cable and ground Wire

  • The igniter sensor must be mounted on the pilot burner before connecting the wires.
  • Use the 55 in. igniter lead as specified in required by the application
12

Gas Leak Test and Checkout

  • Turn on the gas supply. Use a gas sniffer* or paint the pipe connections upstream of the pilot burner with a rich soap and water solution to check for leaks. Bubbles indicate a gas leak.
  • If a leak is detected, tighten the pipe connections. Stand clear of the main burner while lighting to prevent injury from hidden leaks, which can cause flashbacks in the appliance vestibule
  • If another leak is detected, tighten the adapter screws, joints, and pipe connections.
熬到